LOCATION

S-1, 24-C, Sunset Lane No.1, Phase II (ext) DHA, Dha, Karachi, Sindh, Pakistan

DESCRIPTION


MICHLON (China) Coating Thickness Gauge Model MK-04B with External Probe

This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint,enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals. The External probe can work on both principles, magnetic induction and the eddy currents. The probe can automatically detect the substrates type (Magnetic or not), and calculate the coating thickness and display it fast. There are five data groups, and readings will be automatically stored to memory for general groups (Not for direct group).

Each group has individual statistics, alarm limit settings and calibration. User can recall and delete specified readings easily. User does all operations via standard menu so easily. User can press the CAL button to start calibration freely.

Product Specification

Display Type Digital

Least Count 0.1 micron

Measuring Range 0 to 1500 um

Accuracy +/- (3% of readings+2um),+/- (3% of readings + 0.078mils)

Weight 92g (3.24oz)

Size 118 x 56 x 30 mm

Resolution 0.1 micron

Coating Paint,plating,plastic,powder,spray,nickel,zinc,chrome etc

Memory 10 groups (60 readings each)

Power supply Two 1.5V AAA battery

Features

128x128 dot matrix LCD display, standard menu operations

Two measure mode single and continuous

Two group mode direct (DIR) and general(GEN), readings will be lost when power off in direct mode, and not be lost in

general mode. 80 readings can be stored for each group

Zero point calibration and multi-point calibration(up to 4 points) for each group

User can recall, delete specified readings, or delete group readings

Statistics display mean, minimum, maximum and standard deviation

Three probe mode auto, magnetic and eddy current

User can set high or low limit alarm for each group

Power off automatically

USB interface to data transmission

Low battery and error indication

More Specification

Measuring principle Magnetic induction (F-probe) and eddy current (N-probe)

Calibration One to four point calibration, zero calibration

Data Group One direct group (readings not be stored to memory), four general group (readings can be stored), and each group have individual statistics, alarm settings and calibration

Statistics No. of readings, mean, minimum, maximum and standard deviation

Units um, mm and mils

Alarm User can set the high/low alarm, and alarm icon displayed on LCD when over the limit

Minimum curvature radius convex 1.5mm(59mils) and concave 25mm(984mils)

Minimum measuring size Diameter 6mm(236mils)

Minimum thickness of substrate F-probe 0.5mm(0.02"), N-probe 0.3mm(0.012")

Computer interface Download data via USB interface

Operation temperature 0 to 40(32 C to 104 C)

Storage temperature -20 to 70(-4 C to 158 C)

S-1, 24-C, Sunset Lane No.1, Phase II (ext) DHA, Dha, Karachi, Sindh, Pakistan

Mention that you found this ad on DealMarkaz.pk when you call.

یہ شاپنگ ویب سائیٹ نہیں ہے لین دین میں نقصان کی ذمہ داری آپ کی اپنی ہو گی۔
Published 2 years ago
Views 134
Ad Id 151711